BASrouterLX
High-Performance BACnet
®
Router
INSTALLATION GUIDE
INTRODUCTION
The BASrouterLX is a high-performance BACnet router providing stand-alone
routing between BACnet networks such as BACnet/IP, BACnet Ethernet, and
BACnet MS/TP. Besides its high-speed processor, it has advanced features such
as MS/TP slave proxy support (allowing auto-discovery of MS/TP slaves) and
MS/TP frame capture and storage for use with Wireshark
®
. Up to 50 BBMD
entries can be made. The BASrouterLX has two physical communication ports
a 10/100 Mbps BACnet/IP Ethernet port and an optically isolated EIA-485 port
for MS/TP. A USB port is included for future use. Router configuration is
accomplished via a web page
Versatile Routing Between …
BACnet/IP and BACnet MS/TP
BACnet Ethernet and BACnet MS/TP
BACnet/IP and BACnet Ethernet
BACnet/IP and BACnet Ethernet and BACnet MS/TP
Two BACnet/IP networks
IP Network Support
Web server for commissioning and troubleshooting
MS/TP capture using Wireshark®
BACnet/IP Broadcast Management Device (BBMD)
Foreign Device Registration (FDR)
Flexible Communications
10/100 Mbps Ethernet with auto-negotiation and Auto-MDIX
Supports MS/TP slave auto-discovery and proxy
Optically isolated MS/TP port
MS/TP baud rates range from 9.6115.2 kbps
Convenient Installation
24 VAC/VDC (± 10%), 4763 Hz input voltage
Din-rail mounted
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - BASrouterLX

BASrouterLX High-Performance BACnet® Router INSTALLATION GUIDE INTRODUCTION The BASrouterLX is a high-performance BACnet router providing stand-alon

Seite 2 - Disclaimer

TD120100-0IC 10 NOTE: If using shielded cable, connect to chassis at only one point. Wire size may be dictated by electrical codes for the area

Seite 3 - SPECIFICATIONS

TD120100-0IC 11 After removing the router cover, three jumpers are accessible on a 6-pin jumper block located near the EIA-485 connector. These

Seite 4 - Figure 3 — EIA-485 Jumpers

TD120100-0IC 12 NEED MORE HELP INSTALLING THIS PRODUCT? The product features embedded help which can be useful during installation. Wh

Seite 5 - Mechanical

TD120100-0IC 2 Trademarks Contemporary Controls, ARC Control, ARC DETECT, BASautomation, EXTEND-A-BUS, RapidRing, and CTRLink are trad

Seite 6

TD120100-0IC 3 SPECIFICATIONS Electrical (± 10%) Input voltage: 24 V 24 V Input power: 6 W 10 VA Input frequency: N/A 47–63 Hz (Intended

Seite 7

TD120100-0IC 4 Environmental Operating temperature: 0°C to +60°C Storage temperature: –40°C to +85°C Humidity: 10% to 95%, non-condensing

Seite 8

TD120100-0IC 5 Mechanical Figure 4 — BASrouterLX Dimensional Drawing

Seite 9 - CABLING CONSIDERATIONS

TD120100-0IC 6 POWER The BASrouterLX requires 24 VAC or 24 VDC and draws a commensurate amount of current. The recommended conductor

Seite 10 - MS/TP PORT

TD120100-0IC 7 For devices that share a power source with our product, see Figure 6 for proper 2-wire bus connections and Figure 7 for proper 3-w

Seite 11 - TD120100-0IC

TD120100-0IC 8 For devices that do not share power with our product, see Figure 8 for proper 2-wire bus connections and Figure 9 for proper 3-wir

Seite 12 - DECLARATION OF CONFORMITY

TD120100-0IC 9 Limited Power Sources The router should be powered by a limited power source complying with the requirements of the Nationa

Kommentare zu diesen Handbüchern

Keine Kommentare